Mantis Bug Tracker

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0007328opensim[REGION] OpenSim Corepublic2014-09-20 16:282014-09-21 11:14
ReporterUnadecal 
Assigned To 
PrioritynormalSeverityminorReproducibilityalways
StatusnewResolutionopen 
PlatformOSWindowsOS VersionXP
Product Version 
Target VersionFixed in Version 
Summary0007328: CONSOLE COMMAND: region restart bluebox <message> <delta delta delta> misbehaves
DescriptionWhen I issue the command:
region restart bluebox "Abandon Sim, imminent restart" 120 120 120
I get the response
"Region TrulyMadly 1 scheduled for restart in 360 seconds".

I would expect a repeat blue box warning to be issued at 120 second intervals, until the 360s countdown is reached and the region restarts, but it restarts after only a 120s interval, so no repeat warnings are issued.

Not sure if this is relevant, but my Opensim.ini has this parameter set:
InworldRestartShutsDown = true
TagsNo tags attached.
Git Revision or version number0.8.0.1
Run Mode Grid (Multiple Regions per Sim)
Physics EngineBulletSim
Script Engine
Environment.NET / Windows32
Mono VersionNone
Viewer
Attached Files

- Relationships

-  Notes
(0026853)
Mata Hari (reporter)
2014-09-21 11:14

The documentation isn't entirely clear so it's hard to know how the region restart time is calculated. I expect one of the following two variations would do what you want:

region restart bluebox "Abandon Sim, imminent restart" 120 240 360
region restart bluebox "Abandon Sim, imminent restart" 360 120 240

Try the first one and if the restart time of the region is pulled from the first delta encountered it would shut down after 120 seconds in which case the second version would likely work.

- Issue History
Date Modified Username Field Change
2014-09-20 16:28 Unadecal New Issue
2014-09-21 11:14 Mata Hari Note Added: 0026853